@ -174,6 +174,59 @@ automation:
reserved_percentage: >-
{{ states('input_number.inverter_battery_reserve') | int }}
# The inverter can only generate 5kW of AC power. IFF the battery is not-full, it can generate 5kW of AC _and_ charge
# battery at up to 6.6kW, which saturates our 8.46 kW of PV
#
# So, preventing the battery from getting full too early on a sunny day will increase our overall yield, because the
# inverter won't have to derate the PV power to 5kW.
#
# Possible approaches:
#
# 1. Set general charge/discharge limits or start power for charging from PV[1][2]
# Unfortunately, it seems like these registers don't work on my inverter SH5.0RS, so this avenue is out.
# 2. When PV is >5.0kW and battery is not full (but not too low), set forced charging mode and set the charging power
# to be `PV power - 5.0kW` to maintain 5kW of AC constantly. Unfortunately, forced charge/discharge power register
# (13052) can't be set over Modbus (just ignored). So this option is out _at least until_ this is fixed or I have a
# way to programmatically set this using the SunGather HTTP method (i.e. WiNet-S)
# 3. Set battery mode to Stop when all of:
# * Cloud cover is low / weather is sunny
# * PV power is higher than household demand (by some margin, like 1.5x to minimise grid buying)
# * battery is not too low nor full
# * the forecast has enough remaining in the day to fill battery AND cover remaining household usage (or a proxy
# for this like, `forecast > 2*kWh_till_battery_full`)
#
# [1]: https://discord.com/channels/936031869001158666/1008992991643455529
# [2]: https://discord.com/channels/936031869001158666/936031869001158669/1011882768021590036
- id: 05bdc8eb58714c26c2fe
alias: Inverter - maximise output
mode: restart
trigger:
- platform: numeric_state
entity_id: sensor.inverter_pv_power
above: 4900
for:
minutes: 1
- platform: numeric_state
entity_id:
- sensor.inverter_battery_level
- sensor.inverter_active_power
- sensor.home_weather_cloud_coverage
- sensor.home_weather_forecast_cloud_coverage
- sensor.solcast_forecast_remaining_today
- platform: state
entity_id:
- sensor.home_weather_forecast_condition
- sensor.home_weather_condition
- weather.home
- weather.home_hourly
- weather.home_weather
variables:
kwh_until_full: >
{{ 12.8 * (1.0/(100 - states('sensor.inverter_battery_level') | float)) }}
condition:
- "{{ }}"
action: []
script:
inverter_set_battery_reserve:
alias: "Set inverter battery reserve"

View File

@ -9,8 +9,8 @@
},
"0x00158d0008091c32": {
"contact": false,
"voltage": 2995,
"battery": 41,
"voltage": 3005,
"battery": 44,
"temperature": 19,
"linkquality": 255,
"device_temperature": 21,
@ -49,7 +49,7 @@
"battery": 36,
"temperature": 21,
"linkquality": 255,
"device_temperature": 23,
"device_temperature": 24,
"power_outage_count": 41
},
"0x5c0272fffee93bae": {

View File

@ -640,6 +640,16 @@ config:
show_zoom: true
type: custom:bom-radar-card
zoom_level: 8
- entities:
- entity: sun.sun
- entity: weather.home_weather
- entity: sensor.home_weather_condition
- entity: sensor.home_weather_forecast_condition
- entity: weather.home
- entity: weather.home_hourly
- entity: sensor.home_weather_cloud_coverage
- entity: sensor.home_weather_forecast_cloud_coverage