44 lines
1.3 KiB
Rust
44 lines
1.3 KiB
Rust
use sungrow_winets::*;
|
|
|
|
// The documented register for setting the charge/discharge power for forced mode is 13052.
|
|
//
|
|
// HOWEVER, this register can't be set (neither via Modbus nor via WiNet-S register setting). On the other hand, the
|
|
// Energy Management Parameters tab lets you set this value, but inspecting the web requests reveals it uses register
|
|
// 33148!
|
|
//
|
|
// This example, therefore, uses register 33148. However, unlike the documented 13052, the value here is set in
|
|
// multiples of 10W (e.g. `200` is 2000 Watts).
|
|
#[tokio::main]
|
|
async fn main() -> Result<(), Error> {
|
|
tracing_subscriber::fmt::init();
|
|
|
|
let host = std::env::args()
|
|
.nth(1)
|
|
.expect("must pass host/IP of WiNet-S as first argument");
|
|
|
|
let power: u16 = str::parse(
|
|
&std::env::args()
|
|
.nth(2)
|
|
.expect("pass power in watts as second argument"),
|
|
)
|
|
.expect("invalid uint");
|
|
|
|
let client = Client::new(host).await?;
|
|
|
|
let was = client
|
|
.read_register(RegisterType::Holding, 33148, 1)
|
|
.await?;
|
|
|
|
println!("power was {} W", 10 * &was[0]);
|
|
|
|
client.write_register(33148, &[power / 10]).await?;
|
|
|
|
let is = client
|
|
.read_register(RegisterType::Holding, 33148, 1)
|
|
.await?;
|
|
|
|
println!("power is now {} W", 10 * &is[0]);
|
|
|
|
Ok(())
|
|
}
|